Emergency Generator Design

New York Engineers provide the emergency generator design services for skyscrapers in case of a power outage. Our MEP Engineers suggest solutions based on applicable local codes, load requirements, and relevant standards.

shutterstock_1049493110

Solution for Every Building Size

Our professionals will have a solution for both high-rise and low-rise buildings based on laws and regulations enforced by the authorities.

shutterstock_1049493110

Stay Legal, Stay Stress-Free

To facilitate safety and comfort both, our engineers use NFPA standards, Chicago Building codes and Chicago Electric code in their design process, to provide you with utmost safety and functionality in your system.

shutterstock_1049493110

Eco-friendly Design

From loud noises to greenhouse emission and from ventilation to other healthcare considerations, we got you covered.

Get In Touch

WHY DO YOU NEED EMERGENCY GENERATOR? 

 
brasil-brazil-buildings-45917

High Rise and Low Rise Buildings

Legally speaking, our MEP engineers decide this based on the factor of the building you’re living in. Chicago City Building Code has made it mandatory for office buildings, both high-rise, and low-rise, to install an emergency power system.

High-Rise Office Buildings:

  • It is important for all high-rise buildings to essentially implement an emergency generator system based on the official standards set by NFPA.

Low-Rise Office Buildings:

  • These buildings will incorporate it, if an occupied floor is located within seventy-five feet of the fire truck access and if the total area of the floor exceeds fifteen thousand sq. feet or one hundred thousand sq. feet in the case of the whole building.

Get Pricing On a New MEP Design Proposal in Fewer than 24 Hours

Request a proposal →

Types of Emergency Power Generator Designs

 
Emergency Generator Systems

Emergency Generator System Design

This type of power systems design is implemented to provide power to systems which may cause a huge loss if left without power for more than some moments. Some of these design systems include sprinkler systems, fire alarm systems, alarms, life-support systems at the hospitals, chair-lifts, elevators and so on.

The design of this kind of power system is expected to:

  • Provide power before the mark of ten seconds of power loss, automatically.
  • Have separate vents and channels for exhaust
  • Have separate panels
  • Have separate switches
  • Have their very own large rooms or areas, away from other appliances and small objects

nycbackupgenerator

Standby Generator Power System Design

The design should provide a facility for firefighter operations, and emergency evacuations and such.

The design is expected to:

  • Provide power before the mark of sixty seconds of power loss, automatically.
  • Be either separate or joint power system
  • Be fully operational 24/7

naturalgasgenerator

Optional Standby Generator System design

The design for this kind of system is implemented to provide backup power for the comfort of the building attendees and users. These systems provide facility to prevent data losses from computers, provide human comfort through HVAC, keep the security system coverage to 24/7, keep refrigerators, heaters and communication system up and running according to the requirements.

The design is bound to:

  • Provide backup power whenever the owner avails it.
  • Get operational, either manually or automatically
  • May or may not share wiring and components of another power system.

Looking for an MEP / Fire Protection Engineering Poject?

Contact Us →

Aspects You Will Get From NYE Intelligent Generator Design

 
Female engineer wearing hardhat

Installation and Uninstalling Aspect

The NFPA 70 states that UL 2200 Standard for Stationary Engine Generator Assemblies must be a benchmark for all the emergency and standby generators, to be used in the city. On that note, it’s the duty of NYE engineers to practice safety with respect to the installation.

One aspect of safety is to not install the generator or its energy distribution channel in the same room as the main electrical assembly service. So the generators are then placed in an independent and isolated room other precautions like fire-barriers etc.

It is also essential to take care of the piping network. All the piping that passes through the room, that is not related to sprinkler systems or cooling systems, must go uninterrupted through the room. The fuel tanks which will be used for the generator are the only ones allowed inside the space.

Environmental aspect of engineering

Environmental Aspect

All fuel combustion appliances must be registered with the New York City Department of Environmental Protection. This includes both emergency and standby generators.  Furthermore, our professional engineers cater to the possible dangers of natural hazard like a storm, flooding, sewer spew, and other physical dangers to moisture or materials, as defined in the NFPA 110. All this, while designing for these locations to be readily accessible in all type of hazards.

Preventive Maintenance on the Mechanism of Metal Gears.

Operational Aspect

Our professionals are well-versed and experienced with tackling operational issues related to documentation, charging system for the batteries, inspection of faults, and lighting to visibility and untied small material that may disrupt the system.

Small objects are to be kept away from the room. In essence, objects like small blades, documents, loose paddings, plastic parts or wood fibers should be kept well away from the intake and exhaust channel, although we prefer to keep the room free of these troublesome elements altogether.

Lighting should be adequate, more than 1000 lux in both day and night. It should also never be chain-mounted; rather, it should be fixed hung to prevent oscillations of light under wind pressure and thus accidental damage. They may as well be surface-mounted. The fixtures should also be designed with a thermal capacity to bear high thermal loads. Moreover, they should also be resistant to dust and excess water vapor levels in the air. All these considerations are made by our engineers when designing the proper system for you.

Public Health. Medical Concept with Blurred Text, Stethoscope, Pills and Syringe on Grey Background. Selective Focus.

Healthcare Application Aspect

Most noticeable in the case of medical facilities, the generator system, with its noise and pollution need to be taken special care of to mitigate the effects on the patients, ICUs, and the peace-seeking troubled attendees of the hospitals.

Our professionals are efficient at treating the acoustical flaws of the power generator, too. During the architectural design of a medical facility, the placement phase must be discussed with a proper MEP engineer so that these disturbances are minimum.

electricalmeasurement

Electrical Aspect

The battery system of the generator is designed so that the voltage output never drops below ninety percent, with that being said, there’s also a deployment of an automatic recharge system as the law require. Electrical knowledge is also a core part of designing a power system and so even if you do not understand all of this, know that our engineers do and will make sure that everything is satisfied.

Proper fire-barrier, horizontal assemblies should be incorporated and only the piping of the sprinkler system may be incorporated. The voltage calculation is done prior to clearances for EPS and EPSS system because these may be considered as a variable that depends on the voltage.

Side profile closeup sad young woman with worried stressed face expression and brain melting into lines question marks. Obsessive compulsive, adhd, anxiety disorders

Noise Aspect

We at NYE believe in providing the utmost comfort to our employers, and thus the aspect of noise is given special importance to, aside from the environmental aspect. A generator’s noise may disturb the occupants of a building and reduce the efficiency of work by around 60%. These noises arise from parts like cooling fans, electrical noise, exhaust, and engine block.

The prominent reason for the noise is vibration. Our professionals use especially rubber paddings, isolation springs and dampers to reduce noise pollution within the system and thus reducing overall noise within the building. However, there’s still some noise and therefore the overall placement of generators means dedicating a room to it that is far away from the occupants, especially the busy areas.

One more way to reduce the noise is by using exhaust mufflers, although it requires advanced knowledge of air flow and distances between the ventilators, the air dischargers, and the occupied spaces.

Our engineers, therefore, may deploy special sound attenuators, oversized enclosures and such to the conduit runs to dim the primary pathway for generator noise. 

Natural Gas Installation- Chicago

Fuel Aspect

This is one of the most important aspects of a power generator. Fuel is the direct source of energy and without proper precautions, you might find your machine operation but without fuel. If that’s the case in an emergency situation, you’re in big trouble.

Our MEP engineers have precise calculations for the amount of fuel required for the power generator per hour. Moreover, according to the requirement by the code, a full fuel input for around six hours of operation is measured and made available with a factor of safety. For all emergency situations, our engineers deploy the use of diesel as per the Chicago building code requirements. This diesel is stored on site in the sub-base tank or within a remote tank inside the room.

For residents who consider this overwhelming, the deployment of natural gas is also applicable for R-2 occupancy residential lots. However, as a precaution, as the law required, our engineers deploy a cut-off valve between the supply of gas to the generator and other appliances running on gas.

exhaustfans

Exhaust and Ventilation Aspect

NYE professionals are the masters of computational fluid dynamics, something they’ve been doing for the entirety of their career. If you know anything about this software, it’s two things. One it is tough and requires a degree but the second is how useful it is to plot streamlines and potentials of fluids.

In our case, these fluids are exhaust fumes. On account of the US Environmental Protection Agency compliance of tier four, urea injection and other solutions like catalytic reduction are required, to reduce the amount of pollution.

Our MEP engineers are well-experienced with the sizing, configuration and optimal placement of conduit runs. Our engineers are also well-versed in the application of radiators to reduce the airflow requirements in the room, though this comes with an added adverse effect of reduced engine cooling reliability of the system.

nycgenerator

When Do You Need Emergency Generators?

Generally speaking, homeowners may need emergency generators in the case of uncalled for a power outage, in which case, they would use it for the HVAC comfort, freezers and refrigerators, security systems, and lighting. Community lots may not only get financial benefits but in some cases, the safety of lives on the lot. And industrial lots or hospitals are where the backup power becomes critically important.
New York Engineers has full knowledge about when to incorporate which type of generation system to fulfill your needs and the legal requirements.

Let’s have a look at some of the standards of our engineers, driven directly from the Chicago Building Code.

Emergency Power System:

  • In Assembly Group A, the kind of location where the community gathers up to discuss social, civil or religious agendas
  • The Exit signs in all the buildings, no matter how big or small, which may be used for emergency evacuation system
  • Facilities incorporating fabrication of semiconductor-related goods
  • Any facility with hazardous, toxic, or poisonous chemicals and materials
  • Any high-rise, certain low-rise, and underground offices, hospitals or small or large level industries
  • Prisons, asylums, hospitals, and all the places where the inhabitants may get irritated, violent or lose life due to a power
  • Elevator components related to lights, controls and basic functionality

Standby Power Systems:

  • Elevators that are part of emergency evacuations
  • Controlling the post-fire smoke
  • High-rise, underground, and certain low-rise buildings
  • Airports, in the traffic control towers
  • Locations with hazardous or toxic chemicals or material
  • Electrically powered sliding doors

Optional Standby Power Systems: Not necessarily required by law but it will be good if it can handle these loads,

  • Elevators in high-rise (taller than eighty feet) residential or commercial buildings with occupied floors till the top
  • Fire alarm systems
  • Sprinkler systems
  • Security systems
  • The lighting system in case of emergency

Successful team holding check mark vote sign

Why Hire NYE

If you have read all the aspects that need to be considered and the complexity of the types of generators, buildings and the requirements by law based on the type used, then we must be on the same page regarding one thing.

NYE is the way to go to ensure that all applicable standards are met and all codes compliance, all the way from the design stage until the successful inspection of the Chicago Department of Buildings, without any unnecessary cost, hassle or waste of time. Add to that, you’d be assured of proper safety and technical advice from our professionals, hiring proper technical assistance from the beginning clearly seem to be the most intelligent way to go!

Have an MEP Engineering Project? Talk To Us.

 

"Thank you Jahnavi and team for all of your dedication and hard work on this important project for HANAC and the Corona Community."

John-Napolitano_48x48 John Napolitano, Director of Capital Projects, HANAC

"Things went well, and I want to restate how much I appreciate the Herculean effort your team provided to finish up by today!"

Murray-Levi_48x48 Murray Levi, Principal, MTA Artchitects

"The way we work together, the way they overcome challenges, and the way they deliver impresses me more than other engineers, and I'm one of them!"

Silviu-Herscher_48x48 Silviu Herscher, Director of Capital Infrastructure, The New School