At NearBy Engineers New York Engineers we offer a quality fire protection engineering design service for all stages of a construction or building services project that provide heat, smoke and carbon monoxide detection, Design and specification efficiency and allow automated emergency calls to fire departments.
Our fire protection engineering designs include floor plans, diagrams, schedules, equipment, specifications and construction details relating to fire protection equipment, related fittings and accessories. These are all reviewed, signed and sealed by a licensed professional fire protection design engineer.
Temporal 3 Fire Alarm System service
Temporal 3 Fire Alarm Systems are needed following the enactment of National Fire Protection Association (NFPA) 72 for the internationally standardized evacuation signal, now popularly known as the temporal 3 (T3) pattern.
NearBy Engineers New York Engineers expert fire protection engineers can design and specify temporal 3 fire alarm systems according to the standards set in the right locations and modify existing systems to comply with building codes and NFPA 72 requirements.
We provide a useful temporal 3 fire alarm system design and specification service that helps reduce the likelihood that occupants will fall victim to fire damage due to lack of response.
Coded Fire Alarm System service
Coded fire alarm systems have audible and/or visual alarm signals with distinctive pulsing or coding to alert occupants to a fire condition and to the location or type of device that originates an alarm.
NearBy Engineers New York Engineers team of fire protection engineers can design and specify coded fire alarm systems according to the standards set in the right locations and modify existing systems to comply with NFPA 72 requirements and building codes.
We provide a complete coded fire alarm system design and specification service that helps reduce the likelihood that occupants will become victims of fire damage through lack of response.
Addressable fire alarm system service
Introduced by many manufacturers in the mid-1980s, addressable fire alarm systems, allow you to pinpoint exactly which device has been activated. They are useful in premises with large areas. In them, fire detectors and devices are connected to a central control panel that can determine exactly which detector or call point has initiated the alarm.
NearBy Engineers New York Engineers fire protection engineer team can design and specify addressable fire alarm systems for the correct locations according to current standards and NFPA 72 requirements.
We provide a timely addressable fire alarm system design, specification and inspection
service with addressable alarm panels to monitor the air flow through smoke detectors to prevent the occurrence of false alarms.
Full voice alarm system service
Full voice fire alarm systems are voice-enabled fire alarm and emergency communication systems and installed to alert occupants about fire emergencies. NFPA 72 is the code governing the use of voice alarm communications.
NearBy Engineers New York Engineers can design and specify intelligible full voice fire alarm systems according to current standards and NFPA 72 code.
We provide an accurate full voice fire alarm system design, specification and inspection service to assist in the relocation from areas of high to low risk during a fire emergency.
Carbon monoxide detector service
Carbon monoxide detectors are used to detect the presence of deadly carbon monoxide and can be
Carbon monoxide can be a major hazard where people use engines, furnaces, forges, or any other equipment that use oxygen to produce energy through combustion.
NearBy Engineers New York Engineers can design and specify carbon monoxide detectors according to current standards and NFPA 72 code.
We provide a rigorous carbon monoxide design, specification and inspection service to assist in preventing fatalities caused by carbon monoxide poisoning.
Heat sensor service
Heat Sensors are designed to detect fires, which are especially high in flames and emit little smoke at the start and may be hard wired or battery operated, electronic or mechanical, fixed-temperature and/or rate-of-rise types.
NearBy Engineers New York Engineers team of expert fire protection engineers can design and specify heat sensors according to current standards and NFPA 72 code.
We provide a complete heat sensor design, specification and inspection service to reduce the likelihood of fatality from a fire.
Fire alarm control panel service
A fire alarm control panel (fire alarm control unit or fire alarm panel) is a controlling component of a fire alarm system. Each panel receives information from devices designed to detect and report fires, monitors their operational integrity and provides automatic equipment control, and information transmission necessary to prepare the facility for a fire based on a predetermined sequence.
NearBy Engineers New York Engineers fire protection engineering team can design and specify fire alarm control panels according to current standards and the NFPA 72 code.
We provide a comprehensive fire alarm control panel design, specification and inspection service to contribute to enhanced life safety.
Combination fire smoke damper service
Fire dampers are used to maintain the required ratings of fire rated barriers (walls, partitions, floors) penetrated by ductwork. They close upon high duct temperature and smoke detection and can ship with override controls to pressurize individual spaces.
NearBy Engineers New York Engineers fire protection engineering team designs, specifies and inspects combination fire smoke dampers to meet current standards and the NFPA 72 code.
We provide a combination fire smoke damper design, specification and inspection service that allows them to meet code.
Duct smoke detector service
Duct smoke detectors provide early detection of smoke and combustion products present in air moving through HVAC ducts. These are designed for prevention of smoke recirculation in air handling system areas. Fans, blowers and complete systems may be shut down in the event of smoke detection.
NearBy Engineers New York Engineers fire protection engineers can design, specify and inspect combination fire smoke dampers to meet current standards and NFPA 72 code.
We provide a combination fire smoke damper design, specification and inspection service that enables them to meet code.
Fire alarm strobe service
Fire alarm strobes are not only useful for way lighting the way but are used for those who are handicapped of hearing to alert them of danger, where fire alarms are unable to. Pulsing light can wake up them from sleep.
NearBy Engineers New York Engineers fire protection engineering team can design, specify and inspect combination strobes to meet current standards and NFPA 72 code.
We provide a fire alarm strobe design, specification and inspection service that enables them to meet code.