Centrifugal Chiller Design

Accurate

If the centrifugal chiller design is inaccurately done, the execution could suffer. NYE makes sure this doesn’t happen to your project.

Efficient

NYE knows how to make every project achieve its most efficient version. You can count on our highly efficient centrifugal chiller designs.

Heavy-duty

We also make sure that your project is bound to last. All components of your centrifugal chiller project are built to last.

Get In Touch

Centrifugal Chiller 3D Design

 
chillerplant

Centrifugal chillers are widely used throughout North America, especially in major cities like New York, Los Angeles, Chicago, and the like. Compared to the other types of chillers, centrifugal types are often the most economical, and it’s the reason why they’re mostly preferred for cooling large buildings. If you need to instate a new centrifugal chiller in your building, you definitely need the right centrifugal chiller design made by expert design engineers like NYE.

New York Engineers can help you set up in position the best industrial centrifugal chiller and deliver the custom capabilities and flexibility you need. We have dealt with a number of large-scale cooling projects across different industries. We can help you come up with centrifugal chillers that can minimize space and simplify operations. We guarantee designing centrifugal chillers that can run 24/7 and stand the test of time.

We can establish the most efficient centrifugal chillers, so you can save on electricity bills and enjoy attractive paybacks you deserve. To do this, we thoroughly analyze your chilled water system to determine what works best for your setup. With NYE, expect to enjoy highly reliable and low-maintenance centrifugal chiller designs.

 

An Overview of Centrifugal Chillers

Before anything else, let’s have a quick overview of centrifugal chillers and find out what makes them different from the other types of chillers.

Basically, centrifugal chillers use a centrifugal compressor to spin the refrigerant vapor which comes from an impeller wheel’s center outward, allowing the centrifugal forces to compress it. Some centrifugal machines make use of more than one impeller for compressing the refrigerant via several stages. Due to that, they are considered to be the most efficient than any compressor type, especially at full loads. Since they only consist of a few moving parts, they only require low maintenance and can last way longer.

The problem with centrifugal chillers is that they are prone to surges (referring to the disruption of the flow of refrigerant vapor during low partial loads) which can result in noise, vibration, and even damage to the compressor. To resolve this, a technique called hot-gas bypass is used as a means of preventing surge but at the cost of a chiller’s overall efficiency.  

Centrifugal chillers have dominated the HVAC market, particularly above the 300-ton division. Larger units can even go up to several thousand tons. Meanwhile, below the 300-ton division, centrifugal chillers aren’t that much used. Whatever type of centrifugal chiller you need, NYE has the right expertise to pull off the best MEP design for the project. We consider every detail of your requirements and the whole structure of the project to bring about the best results.

Get Pricing On a New MEP Design Proposal in Fewer than 24 Hours

Request a proposal →

The Basic Refrigeration Cycle of a Centrifugal Chiller 

 
Water cooled chiller

To give you an idea of how a centrifugal chiller should be designed and what you can expect from our design services, let us first start by knowing its basic refrigeration cycle. Basically, a centrifugal chiller makes use of the vapor compression cycle as a means of chilling water. It then rejects the heat it has gathered from the chilled water along with the heat gathered from the compressor to the water loop which is cooled by a cooling tower.

A centrifugal chiller normally contains four different components which are described below:

  • Evaporator

The evaporator is responsible for removing heat from the chilled water, lowering its temperature as a result. The removed heat is then used for boiling the refrigerant and changing it from liquid to gas.

  • Compressor

The compressor consists of a centrifugal compressor and a prime mover. The centrifugal compressor works pretty much like a centrifugal water pump by raising the temperature and pressure of the refrigerant, a process achieved through the conversion of kinetic energy to pressure.

  • Condensor

The condenser is the complete opposite of evaporator in the sense that it condenses refrigerant from gas to liquid. However, just like the evaporator, it’s also often a shell and tube heat exchanger. Basically, heat raises the cooling water’s temperature, likewise known as condenser water. Afterward, it then carries heat to the cooling tower where it gets rejected outside.

  • Expansion Device

Once the refrigerant is in its liquid form, it will then go through an expansion device whose task is to reduce pressure. It can be a simple system made of an orifice plate or a complex one such as an electronic modulating expansion valve.

Some high-performance centrifugal chillers use either an electronic modulating expansion valve or a thermal expansion valve for excellent modulation alongside a wide range of temperature conditions and capacity. Here at NYE, we make sure that all of the above components are taken into consideration. Efficiency, accuracy, and attention to detail are what we promise.

 

Features of a Highly Efficient Chiller Design

To make sure we can create centrifugal chiller designs that are centered around high efficiency not just in terms of performance but also in overall electrical costs, we have to make sure that the following features are put in place:

  • Compact Design

A significantly lightweight and compact centrifugal chiller design allows you to save a lot of space in your facility. Aside from that, it also makes transport and replacement a lot easier. By attaching downsized components, such as the economizer, we are able to achieve a highly compact but fully functional and highly-efficient chiller. Also, the fact that it’s modular means you can transport parts of the chiller separately even across tight spaces.

  • Two-stage Compressor

Our designs also feature a two-stage compressing cycle which dramatically improves a chiller’s overall energy efficiency. It can also significantly reduce overall operational costs compared to the previous one-stage system. Lastly, this design is geared toward environmental conservation by reducing CO2 emission.

  • Easy and Optimized Modular Installation

A modular design doesn’t just let you transport each module of your centrifugal chiller separately. It also makes for an easier and quicker installation. You can control module-by-module operation by means of several combination options. As a result, you can maximize partial load efficiency. Moreover, the presence of various installation options means you can customize the installation in accordance with your space and cooling demands.

  • Optimized Central Control

We also make sure that our designs feature optimized central control. This allows you to use various control solutions to monitor your entire cooling system with ease. Aside from that, it also lets you control and manage your system anytime and anywhere you want.

  • Improved Partial Load Efficiency

Our design incorporates precision control which can significantly improve the partial load efficiency of your centrifugal chiller. This results in a 54% increase in overall partial load efficiency compared to other two-stage models which run at a fixed speed. As a result, you can enjoy even more savings on your electrical costs.

  • Low-Noise Operation

By simplifying the compressor’s structure, we are able to reduce noise from our chiller designs by up to 74 dB. This makes them applicable for use in areas that require low noise and vibration.

  • Oil-Free Piping Structure

Other than the traditional centrifugal chiller system, we also create designs for oil-free chillers. Compared to traditional chillers, an oil-free system has a simplified piping structure which is made possible by getting rid of any oil-related parts. This means that it’s no longer necessary to replace oil or filters, allowing you to save more time and money.

  • Magnetic and Air Bearing Technologies

The magnetic bearing technology can significantly improve a chiller’s energy efficiency and overall lubrication loss. The air bearing technology, on the other hand, reduces friction loss along with improved overall efficiency. As it’s such an advanced technology, it's often used in aircraft applications and other industries.

Looking for an MEP Engineering Design Services?

Contact Us →

NYE Centrifugal Chiller Design

 
Project design

Our centrifugal chiller designs at NY Engineers provide an excellent solution in terms of energy efficiency, environmental protection, and business cost reduction.

From the various manufacturing plants and industries to hospitals, food supplies, sports facilities, and more, our centrifugal chiller designs play an important role in supplying chilled water while maintaining a constant temperature at all times.

Whether you have a business facility, a clinic, school, data center, or a high rise establishment, our designs will certainly fit your needs. Here are the things you can expect from them:

  • Real-world efficiency – our chiller designs are intended for maximum real-world efficiency in which the majority of the cooling season is spent at off-design conditions.
  • Massive energy savings – with optimized systems and the application of various technologies, you can expect a massive reduction in your energy consumption, reaching up to as much as 30%!
  • Environmental protection – our chiller designs use the R-134A which is an excellent refrigerant used widely in a lot of applications. It’s very efficient particularly in above-zero and mid-range temperatures. Aside from that, it also features zero ozone-depletion potential as well as a very low global-warming potential.
  • Easy maintenance and operation – our designs feature easy maintenance and operation. There’s no need to maintain them regularly, and you can even enjoy optimum performance and operation.
  • Quick Start feature – in the event of an unexpected power failure, our chiller designs have the Quick Start feature which allows the chiller to restart within 25 seconds as soon as emergency power is started.

 

Considerations for Your Chiller Design

In order to have a comprehensive design, we provide some tips that will help assess what you need for your centrifugal chiller.

  • Plan ahead of time so you can evaluate various chiller options and systems, allowing you to decide on a comprehensive chilling system which can suit your budget and the needs of your facility.
  • There is a wide range of chillers out there, each with their own technologies and efficiency rating. Ideally, you want to compare the offers of each manufacturer to the guidelines which have been established by organizations like ASHRAE and more.
  • Only install chillers that you need. You have to decide on the number of chillers you want in your facility and its overall size. Determine whether you want more cooling or not. Keep in mind that if you have more cooling than you need, it will only lead to higher equipment costs and monthly electrical bills.
  • If your facility requires multiple chiller installations, make sure to opt for different-sized machines. Pick a small chiller for light loads and larger ones for larger loads. This way, you’ll be able to achieve high efficiency most of the time. Only add extra chillers when your current chillers are running at near full capacity.
  • Make sure a chiller has a VSD (variable speed drive) in order to maximize overall part-load efficiency. Centrifugal chillers with a variable speed drive are common in the market. You can even have a custom-manufactured system using our designs. Since variable-speed centrifugal chillers are considerably better compared to their constant-speed counterparts, you’ll be able to enjoy excellent efficiency at all times. However, some chiller manufacturers are fairly new to the VSD market, so you might want to conduct additional research first.
  • Use virtual simulations in order to maximize your chiller system’s efficiency. The interaction of the chiller with its components, mainly the condenser, cooling tower fans, and internal cooling loads can affect its overall efficiency. The problem is, it’s quite difficult to analyze them without the help of virtual simulations which can be done on a computer. Fortunately, we at NY Engineers can also help you in that aspect. Before we give you the final design, we make sure to provide you with a 3D presentation and simulation so you can know how your chiller will work in your facility under various conditions. This way, you can choose which components should go into your chiller and even determine efficient operation techniques.
  • Pick a chiller which can maintain its efficiency over the entire year. Don’t choose one that’s only efficient during peak loads as it won’t give you the most energy and cost-efficient operation over a year. Instead, go for chillers that will continue running in their utmost efficiency under part-loads conditions they’ll likely experience.

 

Why Choose Us?

For your centrifugal chiller design needs, and any other designing needs for your facility, we at NY Engineers are here to help. We are a team of skilled and experienced professionals in the field of MEP (manufacturing, engineering, and plumbing) design.

Our years of experience in the industry allows us to create highly efficient and foolproof designs using a number of valuable tools like AutoCAD and Revit. By working with us, you can expect high-quality and efficient designs for your facility.

 

Have an MEP Engineering Project? Talk To Us.